Report of a problem (and fix suggestion) about sensor status message parsing #111

@diocorreia

Description

@diocorreia

Hello,

I think to have found a small issue with the parsing of the Sensor Status message. The parsing method stops, when sensor_setting_raw is empty, due to the length field value being 0x7F (128) instead of 0x00 (0). I solved the issue by adding
length = (length % 128) on the line number 165.

length = (property_id[0] >> 1) + 1