Scope: Inspection and gap analysis only, per request — no rewrite performed. This document is the evidence-backed basis for a phased implementation plan, not the plan's execution.

Method: Direct inspection of the repository (app/src/**, frontend/src/**, docs/**, .github/**) as of this assessment. Every claim below either cites a file/line or states explicitly that a grep/search across the relevant trees returned no matches. No file was overwritten during this assessment; only Read/Grep/Bash (read-only) were used. AGENTS.md does not exist in this repository; CLAUDE.md (graphify usage rules) and the existing docs/AGENT_MODE.md, docs/CLINICAL_WORKSPACE.md, docs/ARCHITECTURE.md were read and are treated as authoritative for what's already documented — this assessment does not duplicate them, it extends them toward institutional deployment.

Responsibility taxonomy (used throughout)

Every gap below is tagged with one or more of:

  • [SW] — Implementable in this codebase.
  • [CFG] — Requires institutional configuration/deployment decisions (identity provider, network topology, key management service, retention policy) — code can make it possible, not true by default.
  • [DATA] — Requires a licensed medical dataset/terminology/drug database this project cannot ship (SNOMED CT, RxNorm, a commercial interaction database, UMLS).
  • [CLIN] — Requires clinical validation by qualified clinicians (accuracy studies, adjudicated reference answers, safety review) — no engineering substitute.
  • [LEGAL] — Requires legal, regulatory, contractual, or certification work (BAAs, DPAs, HIPAA Security Rule risk assessment, FDA/MDR/CE classification, KVKK VERBIS registration) that no code change satisfies.

1. Current-state architecture summary

ModelForge Medical is a single-user Electron desktop application (main process + Chromium renderer + preload.ts context bridge — see docs/ARCHITECTURE.md). There is no server component, no multi-tenancy, and no network-facing API other than outbound calls the app itself makes (model providers, MCP servers, evidence-source fetches). Every store is a local file under Electron's userData directory, written through a shared atomic-write helper (app/src/json-store.ts) with corruption recovery (backs up and resets on schema-mismatch, per readJsonWithSchema).

Clinical-specific layer (built this engagement, see docs/CLINICAL_WORKSPACE.md for full detail):

  • Patient Cases (app/src/patient-cases-store.ts) — structured fields with per-field includeInContext opt-in, optional AES-256-GCM encryption at rest (app/src/case-encryption.ts), inactivity-based session lock (frontend/src/lib/use-case-auto-lock.ts).
  • Clinical Assistant (frontend/src/pages/Chat.tsx) — 8-section response contract via system prompt, deterministic pre-model emergency-keyword detection and demonstration-only medication/allergy conflict checking (app/src/medical-safety.ts), transmission preview + opt-in redaction before remote sends.
  • Evidence Library (app/src/evidence-store.ts) — add-by-URL only, extracts <title>/meta-description honestly (never fabricates), no live literature search.
  • Knowledge Graph (frontend/src/pages/KnowledgeGraph.tsx) — per-case field visualization only, explicitly not a medical ontology.
  • Audit & Privacy (app/src/audit-log-store.ts) — a flat, unsigned JSON array of events, capped at 5000 and/or a configurable retention window (AppSettings.auditLogRetentionDays).
  • MCP client (app/src/mcp-client.ts) — rebuilt on the official @modelcontextprotocol/sdk this engagement: real JSON Schema validation (AJV), per-tool trust profiles, progress/cancellation, OAuth 2.1+PKCE for HTTP servers, a code-enforced tool denylist mechanism (used for DICOM MCP's move_series/ move_study).
  • Identity, RBAC, central administration: none exist. app/src/accounts.ts is GitHub/Hugging Face personal-access-token linking for Agent-mode tools (repository browsing, model downloads) — it is not a user-identity system and has no bearing on who is using the ModelForge Medical application itself. Grepping app/src and frontend/src for passport|next-auth|oidc|saml|SAML|OIDC returns no matches. Grepping for RBAC|permission|role.*admin returns matches only in unrelated files (command-sandbox.ts's OS process permissions, json-store.ts's file permissions) — no application-level role concept exists anywhere.

2. Evidence-backed gap analysis (by requested capability area)

2.1 Identity and access management — absent entirely

No login screen, no user object, no session concept beyond "the OS user who launched the app." Confirmed by direct inspection: no SSO/OIDC/SAML/MFA library in either app/package.json or frontend/package.json; no User/Session type in app/src/**; secrets-store.ts and case-encryption.ts are per-device, not per-person. Break-glass, RBAC/ABAC, patient/department-level authorization, and account lifecycle management all require an identity system that doesn't exist as a prerequisite — none of these can be partially retrofitted onto a single-user desktop process without that foundation. [SW+CFG]: an identity layer is buildable, but a desktop Electron app enforcing RBAC against a local install is inherently weaker than a server-mediated one (a user with disk access can inspect/modify local state) — real RBAC for this product shape implies a server-mediated deployment topology (see §5 Target architecture), not just a login screen bolted onto the current single-process app.

2.2 Central institutional administration — absent entirely

app/src/settings-store.ts's AppSettings is a single flat, per-device JSON file (settings-store.ts:1-225, confirmed no organization/centralPolicy/orgPolicy field via grep). There is no concept of an admin pushing policy to a fleet of installs, no remote configuration, no remote revocation, and no organization-wide feature toggle. Agent mode can be disabled per-device by the device's own user (Settings toggle exists for networkToolsEnabled, verificationEnabled, etc.) but not by an administrator remotely — anyone with the app installed can re-enable anything on their own machine. [SW+CFG]: requires a central policy service (or at minimum, a signed policy file distribution mechanism) — pure client-side enforcement without server backing is fundamentally circumventable by whoever has local admin rights on the device.

2.3 PHI and sensitive-data protection — partial, one store only

PHI-bearing stores identified by inspection:

Store File PHI risk Encryption today
Patient cases patient-cases.json / .enc.json High — allergies, meds, conditions, notes Yes, opt-in AES-256-GCM (case-encryption.ts)
Chat sessions sessions-store.tssessions.json High — case context gets pasted/typed directly into chat messages, model responses No
Evidence sources evidence-store.tsevidence-sources.json Low (URLs/metadata only, no patient data by design) No (not needed)
Audit log audit-log-store.tsaudit-log.json Low by design (detail documented as non-clinical, never enforced at the type level) No
RAG embeddings app/src/rag.ts (per docs/ARCHITECTURE.md) High if a clinical document is embedded Not inspected in this pass — flag for follow-up; likely unencrypted like sessions.
Exported files data-transfer.ts-driven exports (session/all export) High No — exports are plaintext by construction
Electron cache/temp Chromium's own disk cache, crash dumps Unknown/high Not addressed at all — outside this app's direct control without Electron-level hardening
Logs logger.ts rotating file logs Medium — depends on what gets logged; not audited for PHI leakage in this pass Not addressed
Backups None exist — no backup mechanism at all currently N/A N/A

This is the single largest concrete gap: chat session history — where actual clinical conversation content lives, arguably the highest-PHI-density store in the app — has no encryption at rest, while only the structured Patient Case store does. A user could enable case encryption, feel protected, and still have full clinical detail sitting in plaintext sessions.json from every conversation. [SW] extending case-encryption.ts's pattern to sessions is directly buildable; [SW] a temp-file/cache audit is buildable; [CFG] enterprise key management (HSM/KMS-backed keys, rotation) requires infrastructure this app doesn't have and a passphrase-only design (as built) cannot satisfy on its own; [LEGAL] BAA/DPA and zero-retention configuration metadata are provider contracts, not code.

De-identification: medical-safety.ts's redactIdentifiers is regex-only (email/phone/SSN/MRN/DOB patterns — medical-safety.ts, confirmed via docs/CLINICAL_WORKSPACE.md's own explicit caveat) and is documented in-repo as not clinical-grade (HIPAA Safe Harbor requires handling free-text narrative mentions of names/locations/rare ages/device IDs, which regex cannot reliably catch). [DATA+CLIN] — a real de-identification engine needs either a licensed NLP de-identification service or a clinically-validated model, not a regex list.

2.4 Audit and accountability — partial, not tamper-evident, no real actor identity

audit-log-store.ts records id, timestamp, actionCategory, targetType?, targetId?, detail? plus (added this engagement) MCP-specific fields. Confirmed by direct inspection (grep -n 'hash|sign|hmac|checksum' audit-log-store.tsno matches): the audit log has no cryptographic integrity protection whatsoever. It is a flat JSON array anyone with filesystem access can edit with a text editor, with no hash chain, no digital signature, and no append-only enforcement at the OS or application level. There is also no authenticated actor on any event — because there's no identity system (§2.1), "who did this" cannot be recorded beyond "whoever had the app open." No SIEM export, no central aggregation (every install's audit log is local and isolated — an institution running 200 clinician workstations has 200 disconnected audit logs, not one), no access-review report generation, no automated security alerting. [SW]: a hash-chained or signed log format, structured export, and a SIEM-compatible output format (CEF/syslog) are all directly buildable without external dependencies. [SW+CFG]: central aggregation requires either a server component or a defined export/ship-to-SIEM pipeline (Filebeat, Fluentd, etc.) configured per institution.

2.5 Clinical interoperability — absent entirely (by design, per README)

No FHIR client, no SMART on FHIR, no HL7 v2 parser, no CDA handling anywhere in app/src or frontend/src (confirmed via grep across both trees — zero matches for FHIR|HL7|SMART). DICOM support is MCP-tool-mediated only (dicom-mcp preset, docs/CLINICAL_WORKSPACE.md's "Medical MCP integrations" section) — the app calls an external, community-maintained, explicitly-prototype MCP server for DICOM metadata queries; it does not itself speak the DICOM protocol, has no patient-matching logic, no duplicate detection, and (correctly, per the existing design) no write-back capability of any kind. Turkish SBYS/e-Nabız integration does not exist in any form. [SW]: a read-only FHIR R4 client (patient/encounter/condition/medication resource fetch) is buildable as a new MCP-server-equivalent integration, following the same pattern already established for DICOM MCP (a scoped, denylist-enforced, warning-banner integration) — but this is genuinely large new work, not a gap-fill. [LEGAL+CFG]: SMART on FHIR requires an institutional EHR's app-registration process; e-Nabız requires Turkish Ministry of Health authorization that is explicitly outside engineering scope.

2.6 Medical terminology — absent entirely

No SNOMED CT, LOINC, RxNorm, ICD-10, UMLS, or UCUM handling anywhere in the codebase (confirmed via grep — the only occurrences of these terms are in medical-safety.ts comments explaining their absence and in docs/CLINICAL_WORKSPACE.md, which this engagement wrote to document that absence honestly). Patient Case fields (conditions, medications, allergies in patient-cases-store.ts) are free-text string arrays with no coded-value binding, no terminology version, and no mapping provenance. [DATA]: SNOMED CT, LOINC, RxNorm, and UMLS are licensed vocabularies (UMLS requires a UTS license even for research use) — none can be bundled into an open-source-adjacent product without a license agreement per institution. [SW]: the integration surface (a terminology-lookup abstraction, coded-value fields alongside free text, UCUM-based unit normalization for lab values) is buildable now, ready to plug in a licensed terminology server later.

2.7 Medication and allergy safety — demonstration-only, explicitly labeled as such

checkMedicationConflicts() (medical-safety.ts) uses two small hardcoded tables: ALLERGY_CLASS_SYNONYMS (3 classes: penicillin, sulfa, NSAID) and KNOWN_INTERACTIONS (5 pairs: warfarin+aspirin, warfarin+ibuprofen, MAOI+SSRI, sildenafil+nitrate, metformin+contrast dye). The in-repo comment on KNOWN_INTERACTIONS states verbatim: "NOT a substitute for a licensed drug-interaction database (e.g. First Databank, Lexicomp, Multum)." Every UI surface that renders a warning from this function (PatientCaseDetail.tsx) appends "Generated by simple keyword matching, not a licensed drug-interaction database. Verify independently." This labeling is a real, load-bearing safety control — it correctly prevents the single most dangerous failure mode of a system like this (silent false confidence from an absent warning) by making the limitation unavoidably visible at the point of use. No cross-sensitivity beyond the three allergy classes, no duplicate-therapy detection, no dose-range checking, no renal/hepatic adjustment, no pregnancy/age/weight/pediatric logic, no formulary support. [DATA]: a real medication-safety engine requires a licensed database (First Databank/Multum/Lexicomp-class) — this is a data-licensing problem, not an engineering one. [SW]: the abstraction boundary — a MedicationSafetyProvider interface checkMedicationConflicts() could be refactored behind, with the current demonstration table as the default/fallback implementation and a licensed-database adapter pluggable per institution — is directly buildable now and is the concrete, correctly-scoped "software responsibility" here.

2.8 Clinical AI validation — absent entirely

No intended-use statement beyond the product-boundary language in README.md ("clinical decision-support... not an autonomous diagnostician"). No validation dataset, no clinician-adjudicated reference answers, no hallucination/harmful-omission metrics, no sensitivity/specificity/calibration measurement, no subgroup evaluation, no acceptance thresholds, no silent-mode prospective evaluation pipeline, no human-factors/usability study. This entire category is [CLIN] — it cannot be satisfied by code changes at all. The one thing engineering can do is instrument the product to make such a study possible later (structured logging of model outputs against the response contract, a review/adjudication UI for clinicians to mark outputs correct/incorrect) — that instrumentation does not exist today either. [SW]: build the instrumentation (structured output logging, a clinician-review UI, a metrics pipeline) now; [CLIN]: the actual validation study itself is not an engineering deliverable under any circumstance.

2.9 Model governance — absent entirely

AppSettings.defaultModel and per-session model string (sessions-store.ts:ChatSession.model) are free-text identifiers with no version pinning beyond whatever string the user typed, no model card, no approved-use flag, no evaluation gate before a model becomes selectable, no drift detection, no periodic revalidation requirement, no reproducibility guarantee (temperature/seed are user-configurable per session but nothing prevents a user from changing them turn-to-turn). System-prompt/prompt-preset versioning exists in a limited form — PromptPreset.versions (schemas.ts) keeps a history when a saved prompt is edited — but this is a convenience feature, not a governance control (no approval workflow, no change-control gate). [SW]: an approved-model registry (institution-curated list of {provider, modelId, version, approvedUseCases, approvedBy, approvedAt}) gating what's selectable in the model picker is directly buildable and is a natural extension of the existing mcp-presets.ts/trust-profile pattern already used for MCP servers. [CLIN]: deciding which models are approved for which use cases is a clinical/governance decision, not one code can make.

2.10 Output safety — partial

What exists: the 8-section response contract (prompt-level, not enforced), pre-model deterministic emergency detection (checkForEmergencyFlags — genuinely model-independent, a real control), the "Not verified" badge on every assistant message (Chat.tsx's MessageBubble), transmission preview before remote sends, and (built but not wired into the UI — confirmed via grep, checkCitations is only referenced from its own test file) a citation-verification function that checks a model's inline citation markers against known Evidence Library sources. Gap: there is no structured validation of a model's response against the 8-section contract — a model that skips "Uncertainty and limitations" or fabricates a citation is not caught by anything today; the contract is a system-prompt instruction only, exactly as docs/CLINICAL_WORKSPACE.md already discloses. No abstention enforcement (a model can answer confidently even when the contract asks it to say "insufficient data"). No mechanism requires an identifiable clinician's sign-off before a model-drafted note (e.g. a SOAP note) is treated as final — ClinicalNote.author (patient-cases-store.ts) does distinguish "clinician" | "model-inference" provenance, which is good, but nothing enforces a review step before a model-inference note could be acted on. [SW]: structured-output validation (parse the response for the 8 required section headers, flag a response missing any), wiring checkCitations into the chat UI, and a review/sign-off gate on clinicalNotes are all directly buildable now.

2.11 Evidence quality — partial

Evidence Library (evidence-store.ts) never fabricates title/organization/date — confirmed by its own test suite (evidence-store.test.ts's "never fabricates a title when none is found"). This is real and correctly built. Gaps: no automatic claim-to-source traceability from a model's answer back to a specific Evidence Library entry (the citation-checking function exists but isn't wired in, per §2.10); no retraction awareness; no evidence grading (GRADE-style strength-of-evidence labeling); no guideline-versioning; publication/retrieval dates are captured (retrievedAt, publishedOrUpdated) but not surfaced prominently enough to distinguish "current" from "possibly outdated" evidence in the UI. Patient facts/retrieved evidence/model inference are structurally separated at the data level (ClinicalNote.author, CaseField.includeInContext, Evidence Library as a distinct store) — this separation exists and is a real strength; it's the rendering of that separation in the chat transcript itself (as opposed to the case page) that's incomplete.

2.12 Operational readiness — absent

No centralized monitoring (single-device app, nothing to centralize into). No HA concept (desktop app). No backup mechanism of any kind exists — a user's Patient Cases, chat history, and audit log live only on their local disk with no built-in backup, encrypted or not. No defined RPO/RTO. .github/workflows/ci.yml and release.yml exist and run tests/build/typecheck plus a release-asset verification step (confirmed by direct inspection), but no dependency/SBOM scanning step was found (grep -n 'npm audit|codeql|security' ci.yml → no matches) and no .github/dependabot.yml exists. electron-builder update signing is explicitly not configureddocs/DEVELOPMENT.md's own "Adding signing later (not currently configured)" section confirms every installer today ships with an "unknown publisher" warning, and electron-updater (present in app/package.json) auto-updates without a code-signing chain of trust in place. [SW]: SBOM generation (npm sbom / CycloneDX, trivial to add to CI), Dependabot config, and a documented incident-response runbook are directly buildable now. [CFG]: code-signing certificates, a backup destination/schedule, and defined RPO/RTO are institutional decisions layered on top of buildable mechanisms.

2.13 Agent and MCP security — strong relative to the rest of the app, with one explicit known gap

This is the most mature area, largely because of this engagement's Part A/B MCP rework (docs/CLINICAL_WORKSPACE.md's "MCP client architecture" section): AJV-validated tool schemas, per-tool trust profiles (never blanket server trust), OAuth 2.1+PKCE with RFC 8707 resource-indicator scoping, a code-enforced tool denylist (proven against DICOM's move_series/move_study), PHI transmission preview before remote MCP calls, structured audit binding, and untrusted-description rendering. Explicit, documented gap: docs/AGENT_MODE.md states directly — "Windows has no equivalent lightweight primitive [to bubblewrap/sandbox-exec] — there's no OS-level confinement there, only the [destructive-command] blocklist... plus resource-monitor.ts limits." This means on Windows specifically, run_command and run_code rely entirely on a denylist of known-dangerous patterns rather than real OS-level sandboxing — a materially weaker isolation guarantee than macOS/Linux for the exact same feature. There is no institutional trusted-MCP-server registry (any user can add any MCP server locally — this is by design for a single-user app, but is a gap for institutional deployment where an admin should be able to restrict which MCP servers are addable at all), no network-egress control beyond the existing networkToolsEnabled global on/off toggle, and no least-privilege service identity concept (there are no services — everything runs as the OS user). [SW]: an institutional MCP-server allowlist (server URL/command must match an admin-approved list) is a direct, buildable extension of the existing preset/trust-profile pattern. [CFG]: true Windows sandboxing would require either a fundamentally different process-isolation approach (a Windows container, AppContainer/Job Object-based confinement) — a genuinely large undertaking, not a quick fix — or accepting the denylist-only posture as a documented, institution-acknowledged risk for Windows deployments specifically.

2.14 Accessibility and human factors — ad hoc, not audited

docs/CLINICAL_WORKSPACE.md's own "Known limitations" section already discloses: "ad hoc aria-* labeling, no full WCAG 2.2 AA audit performed on the clinical pages." No keyboard-only operation audit, no screen-reader testing, no localization validation beyond the existing en/tr dictionary completeness (no clinical-content translation review). The "Not verified" badge and clinical severity/warning styling (destructive-red for emergency banners, warning-amber for medication conflicts) do differentiate facts/warnings/unverified output visually, but this has not been validated for colorblind accessibility or screen-reader announcement priority (an emergency banner should almost certainly be an aria-live="assertive" region — not confirmed as implemented in this pass). [SW]: a WCAG audit pass and aria-live correctness review are directly buildable. [LEGAL]: formal accessibility certification (e.g. VPAT) is a compliance-documentation exercise layered on top of the engineering work.


3. Capability gap table

Capability Current implementation Risk Required improvement Priority Responsibility
Verified identity None — OS-user-only Critical: no accountability, no access control possible Identity provider integration (OIDC/SAML) P0 SW+CFG
MFA None Critical Delegate to IdP (do not build custom MFA) P0 CFG
RBAC/ABAC None Critical Role model + enforcement layer, server-mediated P0 SW+CFG
Break-glass access None High Justification-logged emergency access flow P0 SW
Central policy admin None (per-device settings only) Critical Central policy service, signed policy distribution P0 SW+CFG
Approved model registry Free-text model string, no governance High Curated, admin-approved model list P0 SW+CLIN
MCP/endpoint allowlist User can add any MCP server locally High (institutional context) Admin-scoped allowlist enforcement P0 SW+CFG
PHI inventory/encryption Only patient-cases.json encrypted; sessions.json, exports, RAG store, logs, cache not covered Critical Extend encryption to all PHI-bearing stores; audit temp/cache/log paths P0 SW
Enterprise key management Passphrase-derived key, session-memory only, no rotation High KMS/HSM-backed key option for institutional deployments P0 SW+CFG
Secure deletion Plain file delete (fs.rmSync) Medium Document as best-effort; true secure-erase is filesystem/disk-dependent P1 SW+CFG
Backup encryption No backup mechanism exists at all High Build backup mechanism, encrypted by default P0 SW+CFG
Legal hold None Medium Retention-override flag per case/audit event P1 SW+LEGAL
DLP None Medium Outbound-content scanning before remote send (beyond current redaction) P1 SW
Clinical-grade de-identification Regex-only, explicitly non-clinical-grade High Licensed NLP de-identification service P1 DATA+CLIN
Tamper-evident audit Flat JSON, no hash/signature Critical Hash-chained or signed log format P0 SW
Authenticated audit actor None (no identity system) Critical Depends on §Identity P0 SW (blocked on identity)
SIEM export None High CEF/syslog export, or file-ship pipeline P1 SW+CFG
FHIR R4 (read-only) None High (for real clinical utility) Read-only FHIR client, same pattern as DICOM MCP P0 SW+CFG
SMART on FHIR None High Standard OAuth2 SMART launch flow P0 SW+CFG
Terminology (SNOMED/LOINC/RxNorm/UMLS) Free-text only High Coded-value fields + pluggable terminology service P1 DATA+SW
Licensed medication safety Demonstration table only (explicitly labeled) Critical if mistaken for real clearance MedicationSafetyProvider abstraction + licensed adapter P1 DATA+SW
Clinical validation framework None Critical Instrumentation now; formal study is clinical work P0 SW (instrumentation) + CLIN (study)
Output structured validation Prompt-only contract, not enforced High Parse/validate response structure; wire in existing checkCitations P1 SW
Windows agent sandboxing Denylist only, no OS-level confinement High (Windows installs specifically) Document as risk; evaluate AppContainer/Job Object confinement P1 SW+CFG
SBOM / dependency scanning None found in CI Medium Add SBOM generation + Dependabot to CI P1 SW
Update signing Not configured (docs/DEVELOPMENT.md confirms) Medium Configure code-signing certificates P1 CFG
Accessibility (WCAG 2.2 AA) Ad hoc, undocumented gaps Medium Full audit + remediation pass P2 SW+LEGAL (certification)

4. Threat model

Threat Current exposure Mitigations present Mitigations missing
PHI exposure via stolen/lost device High — most PHI-bearing stores unencrypted (§2.3) Case-encryption for patient-cases.json only; OS-level disk encryption is the user's own responsibility (documented) Full-store encryption, remote wipe, MDM integration
Malicious insider (authorized user misusing access) High — no RBAC, no per-patient authorization, no audit-actor identity Audit trail exists (weak) RBAC, break-glass justification logging, authenticated actors, tamper-evident log
Stolen device with app open/unlocked Medium — session lock exists for case data specifically caseAutoLockMinutes auto-lock (§Encryption/session-lock in docs/CLINICAL_WORKSPACE.md) Whole-app lock (chat/Settings remain reachable per documented limitation), MFA re-auth
Compromised/malicious model provider Medium — remote sends require explicit confirmation, redaction is opt-in Transmission preview, local/remote badge, provider selection is user-controlled No provider attestation/BAA-status tracking, no automatic zero-retention enforcement
Prompt injection via imported clinical documents/attachments Medium — mitigated but not eliminated UNTRUSTED_CONTENT_PREAMBLE framing (Chat.tsx), per-call tool approval, MCP tool descriptions rendered as "unverified" No content-level injection detection/scanning
Unsafe/malicious MCP tool or server Low-Medium — meaningfully hardened this engagement AJV schema validation, trust profiles (never blanket), code-enforced denylist, OAuth scoping, PHI transmission preview No institutional trusted-server registry; any local user can add any server
Supply-chain compromise (dependency) Medium — not actively monitored None found beyond normal npm install SBOM, Dependabot, CI dependency scanning, update-signing chain
Audit log tampering High — trivially editable, no integrity check None Hash chaining/signing, append-only enforcement, central shipping
Windows command-execution escape Medium-High on Windows specifically, Low on macOS/Linux Destructive-command blocklist, resource limits (docs/AGENT_MODE.md) Real OS-level sandbox equivalent to bubblewrap/sandbox-exec
Data exfiltration via redaction bypass Medium — redaction is regex-only and opt-in, off by default Transmission preview shows what's included Clinical-grade de-identification, mandatory (not opt-in) DLP for institutional deployments

5. Target architecture for institutional deployment

The current single-process desktop shape is fundamentally incompatible with several P0 requirements (RBAC, central policy, tamper-evident central audit, SIEM integration) — these require something on the other end of a network connection that the desktop app talks to, not just more local code. A realistic target architecture:

┌─────────────────────────┐        ┌──────────────────────────────────┐
│ ModelForge Medical       │        │ Institutional control plane        │
│ (desktop client,         │◄──────►│  - Identity (OIDC/SAML broker)     │
│  this repository)        │  HTTPS │  - Policy service (feature flags,  │
│                           │        │    model registry, MCP allowlist)  │
│  - Local case cache       │        │  - Central audit ingestion (SIEM)  │
│    (encrypted, short-TTL) │        │  - Key management (KMS-backed)     │
│  - Offline-capable for    │        │  - Backup/DR orchestration         │
│    local-model inference  │        └──────────────────────────────────┘
└─────────────────────────┘

Key architectural decisions this implies:

  1. Identity moves to the control plane. The desktop app becomes an OIDC/SAML relying party, not an identity holder — no custom auth is built in-app.
  2. Audit events are shipped, not just stored locally. Local storage remains (offline resilience) but every event is also forwarded to a central, tamper-evident sink as soon as connectivity allows; local logs stay hash-chained regardless of connectivity so a gap in shipping doesn't create a gap in integrity.
  3. Policy is pulled, signed, and cached. The client periodically fetches a signed policy document (approved models, MCP allowlist, retention rules, feature flags) and enforces it locally, refusing to operate on an expired/unverifiable policy past a grace period — this is how "central revocation" becomes real without requiring permanent connectivity.
  4. Local-first inference is preserved. This is the product's actual differentiator and should not be sacrificed for the control plane — local model inference continues to work fully offline; only identity, policy-refresh, and audit-shipping require connectivity, and each degrades gracefully (cached policy, local audit buffering) rather than failing closed in a way that blocks clinical work.
  5. Key management splits local/central. Case-encryption keys can remain passphrase-derived for individual/small-practice deployments (current design, kept as a supported mode) or be wrapped by an institutional KMS for larger deployments — both modes share the same case-encryption.ts interface, just a different key-provider implementation behind it.

This is a genuinely large architectural addition (a new backend service this repository does not currently have any component of), not a set of patches to the existing Electron app — sizing it accurately matters more than a comforting smaller estimate.


6. Phased implementation roadmap

Dependencies are explicit; nothing after Phase 0 should start before its listed dependency is done, since building on an unstable foundation (e.g. audit fields before an identity system exists to populate the actor) means redoing the work.

Phase 0 — Foundation (blocks all P0 work)

  • Full PHI inventory completion (§2.3's flagged-but-not-fully-inspected stores: rag.ts embeddings, exports, logs, Electron cache/temp).
  • Decide target architecture posture (single-device-only vs. control-plane-backed — §5) — this is a product decision, not an engineering one, and everything downstream depends on it.
  • Acceptance criteria: written PHI inventory covering every store with encryption status; a signed-off target-architecture decision document.

Phase 1 — Identity, RBAC, central policy (P0)

  • Depends on: Phase 0's architecture decision.
  • OIDC relying-party integration; role model (clinician/admin/researcher/ auditor/support) with patient-level/department-level scoping; break-glass flow with mandatory justification text, itself an audited event; central policy fetch-and-cache with signature verification and expiry.
  • Acceptance criteria: no PHI-bearing action is reachable without a verified identity and a role check; break-glass access is itself audit-logged with the justification text; a revoked policy takes effect within the defined grace period even offline-then-reconnected.

Phase 2 — Tamper-evident audit + PHI encryption completion (P0)

  • Depends on: Phase 1 (for authenticated actors on every event).
  • Hash-chain or sign every audit event; extend encryption-at-rest to sessions.json, exports, and any PHI-bearing cache/temp path found in Phase 0's inventory; central audit shipping with local buffering.
  • Acceptance criteria: any out-of-band edit to the local audit log file is detectable; every store in the Phase 0 inventory marked "PHI: high" is encrypted at rest; audit events survive a network outage and ship on reconnection without loss or duplication.

Phase 3 — Model/MCP governance (P0/P1)

  • Depends on: Phase 1 (policy delivery mechanism).
  • Approved-model registry gating the model picker; institutional MCP-server allowlist enforced client-side against the fetched policy; evaluation-gate workflow before a model/MCP server can be marked approved.
  • Acceptance criteria: a non-approved model/MCP server is not selectable in the UI, not just discouraged; an admin can revoke approval and it takes effect per Phase 1's policy-refresh mechanism.

Phase 4 — Clinical interoperability, read-only (P0/P1)

  • Depends on: Phase 1 (identity/authorization — patient-context sync requires knowing who is allowed to see which patient), Phase 3 (an EHR integration is itself a governed "tool").
  • Read-only FHIR R4 client (patient/encounter/condition/medicationrequest resources), SMART on FHIR launch flow, patient matching (deterministic, not probabilistic, to start), source provenance tagging on every imported field.
  • Acceptance criteria: no write-back capability exists at all in this phase (explicitly deferred); every FHIR-sourced field is visibly tagged with its source and retrieval time in the UI, matching the existing ClinicalNote.author provenance pattern.

Phase 5 — Terminology + licensed medication safety (P1)

  • Depends on: Phase 0 (architecture decision affects whether terminology service is local or centrally hosted), a signed data-license agreement (external to engineering).
  • MedicationSafetyProvider abstraction (keep the current demonstration table as the default fallback, explicitly labeled, exactly as today); pluggable terminology-lookup interface; UCUM unit normalization on lab-result entry.
  • Acceptance criteria: swapping the demonstration medication-safety table for a licensed adapter requires no changes outside the adapter implementation; every terminology-coded field records its code system and version.

Phase 6 — Output safety hardening + evidence provenance (P1)

  • Depends on: nothing above — can run in parallel with Phases 1-5.
  • Structured-response validation against the 8-section contract; wire checkCitations into the chat UI; evidence-grading labels in Evidence Library; a review/sign-off gate before a clinicalNotes entry with author: "model-inference" is treated as final.
  • Acceptance criteria: a response missing a required contract section is visibly flagged, not silently accepted; an unresolvable citation marker is rendered as unverified in the transcript, not just internally computed.

Phase 7 — Operational readiness (P1)

  • Depends on: Phase 2 (backup must cover the now-fully-encrypted stores).
  • Encrypted backup mechanism with defined RPO/RTO; SBOM + Dependabot in CI; code-signing for releases; documented incident-response runbook.
  • Acceptance criteria: a restore-from-backup drill succeeds against a synthetic dataset; CI fails the build on a newly-disclosed critical CVE in a direct dependency.

Phase 8 — Accessibility + maturity (P2)

  • WCAG 2.2 AA audit and remediation; aria-live correctness pass on emergency/warning banners; localization validation for clinical content.

7. Proposed data model (institutional deployment)

Scoped to what Phases 1-4 above require; field lists are illustrative, not final schemas.

Organization
  id, name, identityProviderConfig, policyDocumentUrl, dataResidencyRegion

User
  id, organizationId, externalIdpSubject (never a locally-stored password),
  displayName, status (active/suspended/deprovisioned), lastLoginAt

Role
  id, name (clinician|administrator|researcher|auditor|support), permissions[]

UserRoleAssignment
  userId, roleId, scope (organization|department|patient-list), scopeId, grantedBy, grantedAt

Permission
  id, resource (patient-case|audit-log|model-registry|mcp-registry|...), action (view|edit|export|delete|administer)

BreakGlassAccess
  id, userId, patientId, justificationText, grantedAt, expiresAt, reviewedBy?, reviewedAt?

Patient
  id, organizationId, externalIdentifiers[] (MRN + system, FHIR-sourced), matchConfidence

Encounter
  id, patientId, source (manual|FHIR), sourceSystem, occurredAt, provenance

Consent
  id, patientId, scope (ai-assistance|remote-model-use|research), grantedAt, revokedAt?, method

ModelVersion
  id, provider, modelId, versionLabel, approvedUseCases[], approvedBy, approvedAt,
  evaluationReportRef, retiredAt?

ClinicalReview
  id, targetType (chat-message|clinical-note), targetId, reviewerId, outcome
  (approved|rejected|amended), reviewedAt, notes

AuditEvent (extends current AuditEvent — audit-log-store.ts)
  ...existing fields..., actorUserId (was absent — now populated), organizationId,
  previousEventHash, eventHash, signature?

Patient/Encounter/Consent are new concepts — today's PatientCase is a case workspace, not a longitudinal patient record; the two are related but distinct, and this model treats PatientCase as remaining the app's local working document while Patient/Encounter become the institutional-record-linkage layer introduced in Phase 4.


8. Clinical evaluation strategy

  1. Intended-use statement (deliverable, not just a README line): specific clinical workflows in scope (e.g. "SOAP note drafting from clinician-entered findings"), explicitly out-of-scope workflows (autonomous diagnosis, prescribing, ordering — already correctly excluded by design), and target user population.
  2. Reference dataset: representative, de-identified or synthetic cases spanning the intended-use workflows, with clinician-adjudicated reference answers (multiple independent clinicians per case, disagreement-resolution process documented).
  3. Metrics: harmful-omission rate (did the response miss something a clinician would flag as safety-critical), hallucination rate (unsupported claims), citation accuracy (does checkCitations's unverified-marker rate correlate with actual fabrication), abstention correctness (does the system correctly say "insufficient information" when it should), and where applicable to a specific workflow, sensitivity/specificity/calibration.
  4. Subgroup evaluation: performance broken out by age, sex, language (en/tr, per the app's existing i18n support), specialty, and care setting — only where legally and scientifically appropriate for the specific workflow being evaluated, per the request's own caveat.
  5. Acceptance thresholds: defined before the evaluation runs, by clinical stakeholders, not derived post-hoc from whatever the model achieves.
  6. Prospective silent-mode pilot: the system runs alongside real clinical workflows without its output being acted upon, logged and later compared against what clinicians actually did — this is the step between "the demo works" and "clinicians can see this in their workflow."
  7. Human-factors/usability validation: does a clinician under real time pressure correctly notice the "Not verified" badge, the emergency banner, and the medication-conflict caveat, or does alert fatigue cause them to be ignored — this requires observed usability sessions, not a code review.

This entire section is [CLIN] — engineering's role is building the instrumentation (structured logging, the review/adjudication UI referenced in Phase 6) that makes each step measurable, not conducting the study itself.


9. Regulatory-readiness matrix

Jurisdiction Key requirements Current status Gap
Türkiye — KVKK Data controller/processor registration (VERBİS), explicit consent for sensitive (health) data processing, cross-border transfer restrictions, breach notification Not addressed No consent-capture mechanism (§7 Consent model is proposed, not built), no VERBİS registration (institutional/legal, not code), cross-border transfer control depends on data-residency (§5, not built)
Türkiye — Ministry of Health e-Nabız/SBYS integration requirements where applicable, local data-residency expectations for health data Not addressed Requires explicit MoH engagement; out of engineering scope entirely
US — HIPAA/HITECH Administrative/physical/technical safeguards, BAAs with any subprocessor (including model providers), breach notification, minimum-necessary access Encryption-at-rest partial (§2.3), audit partial (§2.4), no BAA-tracking metadata, no RBAC/minimum-necessary enforcement (§2.1) P0 items above (identity, RBAC, full-store encryption, tamper-evident audit) are direct prerequisites; BAA execution with each model provider is a legal step this document cannot complete
US — FDA (Clinical Decision Support) 21st Century Cures Act CDS exemption criteria (does the system tell the clinician the basis for its recommendation and allow independent review, without solely relying on the software) — or, if not exempt, device classification The product's design (structured contract requiring evidence/uncertainty, explicit non-autonomous framing, "Not verified" badging) is consistent with the non-device CDS exemption criteria as currently understood, but this is not a legal determination Requires formal regulatory counsel review of the specific intended-use statement (§8) against current FDA CDS guidance — this is a [LEGAL] determination, not something this assessment can certify
EU — GDPR Lawful basis for special-category (health) data, DPIA for high-risk processing, data subject rights (access/erasure/portability), DPO where applicable No DPIA performed, no data-subject-rights tooling (export exists per-session but not as a formal "right of access" workflow) Erasure is possible (deleteCase) but not audited as a formal GDPR-erasure-request workflow; DPIA is a [LEGAL] deliverable
EU — MDR/IVDR Medical device classification if the system's output directly drives a clinical decision without adequate independent clinician review Same exemption-consistent design as the FDA CDS analysis above Same caveat: [LEGAL] determination required, not an engineering conclusion
EU — AI Act High-risk classification likely for AI used in healthcare decision-support; if high-risk, requires risk management system, technical documentation, human oversight, accuracy/robustness testing, logging Human-oversight design intent exists (non-autonomous framing); risk-management system, technical documentation, and accuracy/robustness testing (§8) do not yet exist Classification itself is a [LEGAL] determination; the technical-documentation and logging requirements substantially overlap with §2.4/§2.8/§2.9's gaps above

No claim of compliance with any of the above is made by this document. Every row states current gaps against the requirement, not a certification.


10. Controls that cannot be solved through code alone

  • Clinical validation, accuracy/safety studies, subgroup evaluation, acceptance thresholds (§8) — [CLIN].
  • Licensed terminology (SNOMED CT/LOINC/RxNorm/UMLS) and licensed medication- interaction databases (§2.6, §2.7) — [DATA].
  • BAAs/DPAs with model providers, VERBİS registration, FDA/MDR/AI-Act classification, DPIA, accessibility certification (VPAT) — [LEGAL].
  • Identity provider selection/operation, KMS/HSM provisioning, backup infrastructure, network topology, code-signing certificate issuance, data-residency hosting decisions — [CFG], i.e. real infrastructure and institutional process, not application code.
  • Deciding acceptable risk posture for Windows agent-mode sandboxing (denylist-only vs. investing in a real OS-level confinement mechanism) is ultimately a risk-acceptance decision for whoever deploys the product, informed by but not resolved by engineering.

11. Tests required for every proposed control

Control area Test types required
Identity/RBAC Unauthorized-access rejection tests per role/scope combination; break-glass justification-required test; session-revocation-takes-effect test
Central policy Signature-verification-failure rejection test; expired-policy grace-period test; offline-then-reconnect policy-refresh test
PHI encryption Round-trip tests per newly-encrypted store (mirroring case-encryption.test.ts's pattern already in the repo); tamper-detection tests (GCM auth-tag failure, as already exists for case encryption)
Tamper-evident audit Hash-chain-break-detection test; out-of-band-edit-detection test; concurrent-write-ordering test
Model/MCP governance Non-approved-model-not-selectable test; policy-revocation-takes-effect test; denylist-enforcement test (mirroring mcp-client.test.ts's existing blockedTools suite)
FHIR integration Read-only enforcement test (no write-capable code path exists at all); patient-matching accuracy test against synthetic data; provenance-tagging-present test on every imported field
Medication safety abstraction Adapter-swap test (demonstration table vs. mock licensed adapter produce compatibly-shaped results); "never treat absence of warning as clearance" — a UI test asserting the disclaimer text is always present alongside any conflict-check result, including zero-warning results
Output structured validation Missing-section-detection test; citation-verification test (extending the existing but unwired checkCitations test coverage into an integration test through the chat UI)
Backup/restore Full restore-from-backup integration test against a synthetic dataset; encrypted-backup-cannot-be-read-without-key test
Accessibility Automated WCAG audit (axe-core or equivalent) in CI; aria-live announcement test for emergency banner

Every test category above should follow the existing repository convention: real logic exercised against synthetic fixtures only (as medical-safety.test.ts, evidence-store.test.ts, and patient-cases-store.test.ts already do), colocated *.test.ts files, no test ever touching real patient data.

12. Deployment decision

Per the requested classification, and strictly on the evidence gathered in this assessment:

Research and clinician-supervised evaluation only. Not for autonomous clinical decisions, production dependency, or use with identifiable patient data, until the Phase 1-2 P0 items above (verified identity, RBAC, tamper-evident audit with authenticated actors, and complete PHI-store encryption) are demonstrably satisfied — not merely implemented, but verified by the acceptance criteria listed in §6.

This matches the deployment-decision options given as: not yet even "de-identified pilot"-ready, because de-identification itself is regex-only and non-clinical-grade (§2.3), and a pilot using de-identified data still needs the audit-integrity and access-control foundation (§2.1, §2.4) to be trustworthy as a pilot at all. The correct entry point today is synthetic-data research and internal clinician evaluation only, exactly as this repository's own test suites already do.