Skip to content

C1: Failure inputs on a treatment step in the configurator (enter, check ranges, save, reopen, edit) #21

Open

Description

@yaniv-kwb

Status: review (built in pull request #28; stays open until the release, D5)

Source

Spec C1 Failure inputs (docs/specs/c1-failure-inputs.md), Change C1 in docs/failure_roadmap.md. The Spec issue does not exist yet.

What to build

Every treatment step in the assessment configurator gets two more fields: failure frequency (failure days per year) and failure duration (minutes). Registered users can save an assessment with these values, and when they reopen or edit it they see the same values again. The values do not change the result yet; the calculation follows in C2.

Tidy-up comes first. The configurator's treatment step form and the personal treatment step form both contain the same minimum ≤ maximum LRV check. It becomes one shared rule that both forms use, and the failure rules are added to it later. This Ticket also adds the first HTTP-level tests. They use Django's test client and a logged-in test user, and they check what a browser or a later request can see.

Delivered on branch c1-failure-inputs as part of the single C1 pull request. The pull request stays open until the release (D5).

Acceptance criteria

  • The minimum ≤ maximum LRV check is defined once and used by both treatment step forms. Nothing changes that a user can notice, and the existing test suite passes unchanged.
  • A schema migration adds failure frequency (a decimal number) and failure duration (a whole number) to the treatment steps of an assessment. Existing rows get failure frequency 0 and failure duration 30.
  • Each treatment step card in the configurator shows both fields below its LRV rows, labelled "Failure frequency (days per year)" and "Failure duration (minutes)". New steps start at 0 and 30, bundled steps included.
  • Failure frequency outside 0–365, and failure duration outside 1–1440 or not a whole number, are rejected with a message on the saved configurator. The duration range is checked even when the frequency is 0.
  • A fractional failure frequency such as 0.5 is accepted.
  • Saving an assessment and reopening it gives back the same failure values for each step. Editing them and saving again stores the new values.
  • Each value stays with its own step when other steps are removed. Two copies of the same bundled step can have different values.
  • An assessment created without failure values, as before the migration, reopens with failure frequency 0 and failure duration 30.
  • An assessment's result and export package are the same with and without failure inputs.
  • All of the above is covered by HTTP-level tests through Django's test client, and the existing test suite passes unchanged.

Blocked by

None (can start immediately)

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests