This repository was archived by the owner on Jan 21, 2021. It is now read-only.
PowerUp.ps1:2466 - Check SystemPath only#258
Closed
Bubbl3H3d wants to merge 1 commit intoPowerShellMafia:masterfrom
Bubbl3H3d:patch-1
Closed
PowerUp.ps1:2466 - Check SystemPath only#258Bubbl3H3d wants to merge 1 commit intoPowerShellMafia:masterfrom Bubbl3H3d:patch-1
Bubbl3H3d wants to merge 1 commit intoPowerShellMafia:masterfrom
Bubbl3H3d:patch-1
Conversation
The current instantiation of code calls the %PATH% environment variable. However, since PowerUp is normally run with the permissions of an unprivileged crappy user in order to privesc, the %PATH% variable is returned as a concatenation of the SystemPath and UserPath. Any exploitable services running as SYSTEM will not call DLLs from the UserPath. Thus, we need to focus on writable folders in the SystemPath only in order to privesc. The proposed change pulls the SystemPath value directly from the registry and places it in the same format as the original code.
Author
|
Submitted to Dev: #263 |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to subscribe to this conversation on GitHub.
Already have an account?
Sign in.
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
The current instantiation of code calls the %PATH% environment variable. However, since PowerUp is normally run with the permissions of an unprivileged crappy user in order to privesc, the %PATH% variable is returned as a concatenation of the SystemPath and UserPath. Any exploitable services running as SYSTEM will not call DLLs from the UserPath. Thus, we need to focus on writable folders in the SystemPath only in order to privesc. The proposed change pulls the SystemPath value directly from the registry and places it in the same format as the original code.