Problem

Reported on poolsteuerung.de (thread p=39074): after a controller restart/timeout, the daily Chlor/pH-Minus dosing sensors in the Home Assistant integration turn unknown. The cause is in this library: get_readings() queries plain getReadings?ALL, and the controller's getReadings.js gates the computed field groups behind feature-flag tokens — plain ALL does not include them:

  • DOSAGE → DOS_*_DAILY_DOSING_AMOUNT_ML, DOS_*_TOTAL_CAN_AMOUNT_ML, DOS_*_REMAINING_RANGE, …
  • RUNTIMES → *_RUNTIME strings
  • PUMPPRIOSTATE → composite PUMPSTATE/HEATERSTATE/SOLARSTATE
  • BACKWASH → backwash counters
  • SYSTEM → SYSTEM_* diagnostics

(the token semantics are already documented above SPECIFIC_READING_GROUPS in const_api.py).

Fix

get_readings() and get_hardware_profile() now send ${QUERY_FULL_REFRESH} = ALL,DOSAGE,RUNTIMES,PUMPPRIOSTATE,BACKWASH,SYSTEM, restoring the documented "complete dataset" semantics.

Verification

  • Live controller (firmware 1.2.5): the mixed query returns exactly the same 419-key payload as plain ALL — 0 keys lost, 0 added, only MEMORY_USED (a live counter) differs in value. The fix is a no-op where plain ALL already works and restores the missing groups where it does not.
  • Full test suite: 261 passed.
  • ruff check clean.

Tests

  • 18 existing URL mocks updated to the full query.
  • New test_get_readings_requests_all_feature_flags pins the query string.
  • Mock server: ALL + tokens now returns the unfiltered payload (matches firmware), covered by a new raw-HTTP test.

Plain `ALL` stopped returning the computed field groups on every firmware
state: after a controller restart/timeout the daily dosing totals
(DOS_*_DAILY_DOSING_AMOUNT_ML and friends), runtime strings, priority-state
composites, backwash counters and SYSTEM_* diagnostics are gated behind the
DOSAGE/RUNTIMES/PUMPPRIOSTATE/BACKWASH/SYSTEM tokens and simply missing from
the response, leaving the matching Home Assistant sensors at 'unknown'
(reported on poolsteuerung.de; getReadings.js documents the tokens as feature
flags, not regex filters).

get_readings() and get_hardware_profile() now send
ALL,DOSAGE,RUNTIMES,PUMPPRIOSTATE,BACKWASH,SYSTEM (QUERY_FULL_REFRESH).
Verified against a live controller on firmware 1.2.5: identical 419-key
payload to plain ALL, so nothing changes where ALL already worked. The mock
server treats ALL plus tokens as no filtering, like the firmware.